如果您的数字显示屏出现任何问题,请执行以下任务以重置显示屏。
Position the OTTOVAC firmly against the surface of the object you want to lift.
Press the power ON/OFF button to turn on the motor and create a seal on the surface of the item you want to lift. The indicator light will flash green when the motor is running. The seal will be created within seconds.
When the sensor detects that maximum pressure is reached, the pump will automatically turn off. For the automatic pump to work, ensure the motor is turned on (the indicator light is solid green) when lifting objects.
When finished, press the power ON/OFF button to turn off the motor.
Press the Pressure release button to break the seal and release the object.
Warning: When the batteries are low, the indicator light will flash green and red. Using the OTTOVAC while the batteries are low may result in injury and damage to the materials being lifted. Always use fully charged batteries before operating the OTTOVAC.
Flashing Green: The pump is building pressure. Normal operation.
Solid Green: Maximum pressure reached. The device is ready to use.
Flashing Red (50 to 60 degrees Celsius): Device is overheating. Move to a cooler area and allow it to cool.
Solid Red (above 60 degrees Celsius): Device is too hot and will not operate. Wait for it to cool down.
Alternating Green and Red: Battery is low. Charge or replace the battery.
If the sealing force decreases while the battery is fully charged, inspect the rubber seal for wear or damage.
Clean the rubber seal with methylated spirit (denatured alcohol).
Replace the rubber seal if it is visibly worn or damaged.
Weight may drop without warning if the safety precautions are not met. The OTTOVAC creates a strong vacuum. If the seal is broken or the allowed weight is exceeded, failure happens suddenly and without any sensory warning. All safety precautions must be observed at all times.
Press the Battery compartment release button to release the AA Battery compartment or Li-ion battery.
Insert 4 x AA alkaline batteries (not included) in accordance with the markings on the AA Battery compartment or Li-ion battery. If you do not adhere to the markings, the OTTOVAC will not work.
Put the Li-ion battery or the loaded AA Battery compartment back into the OTTOVAC.
Press the Power ON/OFF button to turn on the OTTOVAC.
The filter needs to be replaced when it is badly worn or ripped (at the customer's discretion). When lifting clean material, the filter will last longer than when used on dirty or dusty materials.
Turn the device upside down.
Use a screwdriver tip to pry out the old air filter.
Push the replacement filter firmly into place until fully seated.
CAUTION: Under no circumstances should the OTTOVAC be opened for repairs or any other purpose by anyone other than an after-sales service technician authorised by Nemo Power Tools Ltd. Opening the OTTOVAC will invalidate the manufacturer's warranty.